1.
Arq Bras Cardiol ; 118(6): 1085-1096, 2022.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35703645

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a worldwide adopted procedure with rapidly evolving practices. Regional and temporal variations are expected to be found. OBJECTIVE: To compare TAVR practice in Latin America with that around the world and to assess its changes in Latin America from 2015 to 2020. METHODS: A survey was applied to global TAVR centers between March and September 2015, and again to Latin-American centers between July 2019 and January 2020. The survey consisted of questions addressing: i) center's general information; ii) pre-TAVR evaluation; iii) procedural techniques; iv) post-TAVR management; v) follow-up. Answers from the 2015 survey of Latin-American centers (LATAM15) were compared with those of other centers around the world (WORLD15) and with the 2020 updated Latin-American survey (LATAM20). A 5% level of significance was adopted for statistical analysis. RESULTS: 250 centers participated in the 2015 survey (LATAM15=29; WORLD15=221) and 46 in the LATAM20. Combined centers experience accounted for 73 707 procedures, with WORLD15 centers performing, on average, 6- and 3-times more procedures than LATAM15 and LATAM20 centers, respectively. LATAM centers performed less minimalistic TAVR than WORLD15 centers, but there was a significant increase in less invasive procedures after 5 years in Latin-American centers. For postprocedural care, a lower period of telemetry and maintenance of temporary pacing wire, along with less utilization of dual antiplatelet therapy was observed in LATAM20 centers. CONCLUSION: Despite still having a much lower number of procedures, many aspects of TAVR practice in Latin-American centers have evolved in recent years, followingthe trend observed in developed country centers.


FUNDAMENTO: Implante transcateter de valva aórtica (TAVI) é um procedimento adotado em todo o mundo e suas práticas evoluem rapidamente. Variações regionais e temporais são esperadas. OBJETIVO: Comparar a prática de TAVI na América Latina com aquela no resto do mundo e avaliar suas mudanças na América Latina de 2015 a 2020. MÉTODO: A pesquisa foi realizada em centros de TAVI em todo o mundo entre março e setembro de 2015, e novamente nos centros latino-americanos entre julho de 2019 e janeiro de 2020. As seguintes questões foram abordadas: i) informação geral sobre os centros; ii) avaliação pré-TAVI; iii) técnicas do procedimento; iv) conduta pós-TAVI; v) seguimento. As respostas da pesquisa dos centros latino-americanos em 2015 (LATAM15) foram comparadas àquelas dos centros no resto do mundo (WORLD15) e ainda àquelas da pesquisa dos centros latino-americanos de 2020 (LATAM20). Adotou-se o nível de significância de 5% na análise estatística. RESULTADOS: 250 centros participaram da pesquisa em 2015 (LATAM15=29; WORLD15=221) e 46 na avaliação LATAM20. No total, foram 73.707 procedimentos, sendo que os centros WORLD15 realizaram, em média, 6 e 3 vezes mais procedimentos do que os centros LATAM15 e LATAM20, respectivamente. Os centros latino-americanos realizaram menor número de TAVI minimalista do que os do restante do mundo, mas aumentaram significativamente os procedimentos menos invasivos após 5 anos. Quanto à assistência pós-procedimento, observaram-se menor tempo de telemetria e de manutenção do marca-passo temporário, além de menor uso de terapia dupla antiplaquetária nos centros LATAM20. CONCLUSÃO: A despeito do volume de procedimentos ainda significativamente menor, muitos aspectos da prática de TAVI nos centros latino-americanos evoluíram recentemente, acompanhando a tendência dos centros dos países desenvolvidos.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , América Latina , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Arq. bras. cardiol ; 118(6): 1085-1096, Maio 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1383690

RESUMO

Resumo Fundamento: Implante transcateter de valva aórtica (TAVI) é um procedimento adotado em todo o mundo e suas práticas evoluem rapidamente. Variações regionais e temporais são esperadas. Objetivo: Comparar a prática de TAVI na América Latina com aquela no resto do mundo e avaliar suas mudanças na América Latina de 2015 a 2020. Método: A pesquisa foi realizada em centros de TAVI em todo o mundo entre março e setembro de 2015, e novamente nos centros latino-americanos entre julho de 2019 e janeiro de 2020. As seguintes questões foram abordadas: i) informação geral sobre os centros; ii) avaliação pré-TAVI; iii) técnicas do procedimento; iv) conduta pós-TAVI; v) seguimento. As respostas da pesquisa dos centros latino-americanos em 2015 (LATAM15) foram comparadas àquelas dos centros no resto do mundo (WORLD15) e ainda àquelas da pesquisa dos centros latino-americanos de 2020 (LATAM20). Adotou-se o nível de significância de 5% na análise estatística. Resultados: 250 centros participaram da pesquisa em 2015 (LATAM15=29; WORLD15=221) e 46 na avaliação LATAM20. No total, foram 73.707 procedimentos, sendo que os centros WORLD15 realizaram, em média, 6 e 3 vezes mais procedimentos do que os centros LATAM15 e LATAM20, respectivamente. Os centros latino-americanos realizaram menor número de TAVI minimalista do que os do restante do mundo, mas aumentaram significativamente os procedimentos menos invasivos após 5 anos. Quanto à assistência pós-procedimento, observaram-se menor tempo de telemetria e de manutenção do marca-passo temporário, além de menor uso de terapia dupla antiplaquetária nos centros LATAM20. Conclusão: A despeito do volume de procedimentos ainda significativamente menor, muitos aspectos da prática de TAVI nos centros latino-americanos evoluíram recentemente, acompanhando a tendência dos centros dos países desenvolvidos.


Abstract Background: Transcatheter aortic valve replacement (TAVR) is a worldwide adopted procedure with rapidly evolving practices. Regional and temporal variations are expected to be found. Objective: To compare TAVR practice in Latin America with that around the world and to assess its changes in Latin America from 2015 to 2020. Methods: A survey was applied to global TAVR centers between March and September 2015, and again to Latin-American centers between July 2019 and January 2020. The survey consisted of questions addressing: i) center's general information; ii) pre-TAVR evaluation; iii) procedural techniques; iv) post-TAVR management; v) follow-up. Answers from the 2015 survey of Latin-American centers (LATAM15) were compared with those of other centers around the world (WORLD15) and with the 2020 updated Latin-American survey (LATAM20). A 5% level of significance was adopted for statistical analysis. Results: 250 centers participated in the 2015 survey (LATAM15=29; WORLD15=221) and 46 in the LATAM20. Combined centers experience accounted for 73 707 procedures, with WORLD15 centers performing, on average, 6- and 3-times more procedures than LATAM15 and LATAM20 centers, respectively. LATAM centers performed less minimalistic TAVR than WORLD15 centers, but there was a significant increase in less invasive procedures after 5 years in Latin-American centers. For postprocedural care, a lower period of telemetry and maintenance of temporary pacing wire, along with less utilization of dual antiplatelet therapy was observed in LATAM20 centers. Conclusion: Despite still having a much lower number of procedures, many aspects of TAVR practice in Latin-American centers have evolved in recent years, followingthe trend observed in developed country centers.

3.
J Am Heart Assoc ; 10(18): e020682, 2021 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-34546114

RESUMO

Background No study has evaluated the impact of the additional manipulation demanded by multiple resheathing (MR) in patients undergoing transcatheter aortic valve replacement with repositionable self-expanding valves. Methods and Results This study included a real-world, multicenter registry involving 16 centers from Canada, Germany, Latin America, and Spain. All consecutive patients who underwent transcatheter aortic valve replacement with the Evolut R, Evolut PRO, and Portico valves were included. Patients were divided according to the number of resheathing: no resheathing, single resheathing (SR), and MR. The primary end point was device success. Secondary outcomes included procedural complications, early safety events, and 1-year mortality. In 1026 patients, the proportion who required SR and MR was 23.9% and 9.3%, respectively. MR was predicted by the use of Portico and moderate/severe aortic regurgitation at baseline (both with P<0.01). Patients undergoing MR had less device success (no resheathing=89.9%, SR=89.8%, and MR=80%; P=0.01), driven by more need for a second prosthesis and device embolization. At 30 days, there were no differences in safety events. At 1 year, more deaths occurred with MR (no resheathing=10.5%, SR=8.0%, and MR=18.8%; P=0.014). After adjusting for baseline differences and center experience by annual volume, MR associated with less device success (odds ratio, 0.42; P=0.003) and increased 1-year mortality (hazard ratio, 2.06; P=0.01). When including only the Evolut R/PRO cases (N=837), MR continued to have less device success (P<0.001) and a trend toward increased mortality (P=0.05). Conclusions Repositioning a self-expanding valve is used in a third of patients, being multiple in ≈10%. MR, but not SR, was associated with more device failure and higher 1-year mortality, regardless of the type of valve implanted.


Assuntos
Substituição da Valva Aórtica Transcateter , Cateteres , Humanos , Incidência , Razão de Chances , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos
4.
Cardiorenal Med ; 11(4): 166-173, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34261063

RESUMO

BACKGROUND: Acute kidney injury (AKI) has shown to adversely affect outcomes in patients undergoing transcutaneous aortic valve replacement (TAVR), and its correct risk estimation may interfere in procedural planning and strategies. The aim of the study was to test and compare 6 scores in predicting AKI after TAVR. METHODS: We tested 6 scores (the contrast material limit score, volume-to-creatinine clearance ratio, ACEF, CR4EATME3AD3, Mehran model A, and Mehran model B) in a total of 559 consecutive patients included in the Brazilian TAVR registry. RESULTS: All scores had a poor accuracy and calibration to predict the occurrence of AKI grade 1 or 2. All scores improved the accuracy of AKI risk prediction when stratified for AKI grade 2/3 and AKI grade 3 for all scores. The CR4EATME3AD3 was the best predictor of AKI stage 2/3 (AUC: 0.62; OR: 1.12; 95% CI 1.01-1.26; p = 0.04) and AKI stage 3 (AUC: 0.64; OR: 1.16; 95% CI 1.02-1.32; p = 0.02). Mehran models A and B were both good models for AKI stage 3 (AUC: 0.63; OR: 1.10; 95% CI 1.01-1.22; p = 0.05; and AUC: 0.62; OR: 1.10; 95% CI 1.00-1.21; p = 0.05, respectively). CONCLUSIONS: None of the current models demonstrated validity in detecting AKI when its lower grades were evaluated. CR4EATME3AD3 was the best score in predicting moderate to severe AKI after TAVR. These findings suggest that contrast-induced AKI may not be the only factor related to kidney injury after TAVR.


Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco
5.
Heart ; 107(18): 1450-1457, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34127541

RESUMO

In elderly (75 years or older) patients living in Latin America with severe symptomatic aortic stenosis candidates for transfemoral approach, the panel suggests the use of transcatheter aortic valve implant (TAVI) over surgical aortic valve replacement (SAVR). This is a conditional recommendation, based on moderate certainty in the evidence (⨁⨁⨁Ο).This recommendation does not apply to patients in which there is a standard of care, like TAVI for patients at very high risk for cardiac surgery or inoperable patients, or SAVR for non-elderly patients (eg, under 65 years old) at low risk for cardiac surgery. The suggested age threshold of 75 years old is based on judgement of limited available literature and should be used as a guide rather than a determinant threshold.The conditional nature of this recommendation means that the majority of patients in this situation would want a transfemoral TAVI over SAVR, but some may prefer SAVR. For clinicians, this means that they must be familiar with the evidence supporting this recommendation and help each patient to arrive at a management decision integrating a multidisciplinary team discussion (Heart Team), patient's values and preferences through shared decision-making, and available resources. Policymakers will require substantial debate and the involvement of various stakeholders to implement this recommendation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Guias de Prática Clínica como Assunto , Substituição da Valva Aórtica Transcateter/normas , Estenose da Valva Aórtica/diagnóstico , Implante de Prótese de Valva Cardíaca/normas , Humanos , América Latina , Índice de Gravidade de Doença
6.
PLoS One ; 16(5): e0251066, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33984005

RESUMO

BACKGROUND: Chronic kidney disease is commonly found in patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) and has marked impact in their prognosis. It has been shown however that TAVR may improve renal function by alleviating the hemodynamic barrier imposed by AS. Nevertheless, the predictors of and clinical consequences of renal function improvement are not well established. Our aim was to assess the predictors of improvement of renal function after TAVR. METHODS: The present work is an analysis of the Brazilian Registry of TAVR, a national non-randomized prospective study with 22 Brazilian centers. Patients with baseline renal dysfunction (estimated glomerular filtration rate [eGFR] < 60mL/min/1.73m2) were stratified according to renal function after TAVR: increase >10% in eGFR were classified as TAVR induced renal function improvement (TIRFI); decrease > 10% in eGFR were classified as acute kidney injury (AKI) and stable renal function (neither criteria). RESULTS: A total of 819 consecutive patients with symptomatic severe AS were included. Of these, baseline renal dysfunction (estimated glomerular filtration rate [eGFR] < 60mL/min/1.73m2) was present in 577 (70%) patients. Considering variance in renal function between baseline and at discharge after TAVR procedure, TIRFI was seen in 197 (34.1%) patients, AKI in 203 (35.2%), and stable renal function in 177 (30.7%). The independent predictors of TIRFI were: absence of coronary artery disease (OR: 0.69; 95% CI 0.48-0.98; P = 0.039) and lower baseline eGFR (OR: 0.98; 95% CI 0.97-1.00; P = 0.039). There was no significant difference in 30-day and 1-year all-cause mortality between patients with stable renal function or TIRFI. Nonetheless, individuals that had AKI after TAVR presented higher mortality compared with TIRFI and stable renal function groups (29.3% vs. 15.4% vs. 9.5%, respectively; p < 0.001). CONCLUSIONS: TIRFI was frequently found among baseline impaired renal function individuals but was not associated with improved 1-year outcomes.


Assuntos
Rim/fisiologia , Insuficiência Renal Crônica/fisiopatologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Taxa de Filtração Glomerular/fisiologia , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica/fisiologia , Humanos , Testes de Função Renal/métodos , Modelos Logísticos , Masculino , Razão de Chances , Prognóstico , Estudos Prospectivos , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/cirurgia , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
7.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 31(supl. 2B): 159-159, abr-jun., 2021. tab.
Artigo em Português | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1284342

RESUMO

INTRODUÇÃO: A dissecção espontânea de artéria coronária (SCAD do inglês spontaneous coronary artery dissection) é uma causa não aterosclerótica de síndrome coronariana aguda que acomete preferencialmente mulheres jovens. De fisiopatologia ainda não completamente conhecida, pode manifestar-se sob a forma de infarto agudo do miocárdio com (IAMCSST) ou sem (IAMSSST) supradesnivelamento do segmento. A SCAD é a principal causa de infarto agudo do miocárdio no ciclo gravídico-puerperal. A descrição demográfica e angiográfica da SCAD de coorte brasileira é pouco explorada. OBJETIVO: Avaliar o perfil demográfico, angiográfico e os gatilhos de SCAD em uma população brasileira. MATERIAL E MÉTODOS: Estudo retrospectivo e prospectivo de pacientes com SCAD envolvendo 22 Hospitais no Brasil. Revisão de base de dados do REDcap no período de 2010-2021. RESULTADOS: Registraram-se 166 pacientes com SCAD, com idade média de 50,15 ± 10,56 anos (29 a 84 anos) com incidência prevalente no gênero feminino (85%). Os pacientes apresentavam nenhum ou poucos fatores de risco para doença arterial coronariana, incluindo hipertensão arterial (25%), história familiar de doença coronariana precoce (22%), dislipidemia mista (16%) e tabagismo ativo (16%). Seis por cento dos casos de SCAD ocorreram no ciclo gravídico puerperal. A maioria dos casos de SCAD manifestou-se como IAMSSST (47%), com IAMCSST (38%) e angina instável (12%) (Tabela). Entre os fatores desencadeantes, presentes em 57,8% dos casos, destacaram-se: estressor emocional (21,08%) e menopausa (18,07%). A displasia fibromuscular, não investigada sistematicamente, foi observada em poucos casos (4,21%), gestação (0,6%), puerpério (10,24%), estressor físico (5,42%), uso de terapia hormonal (3,60%) e doenças psiquiátricas (2,40%). A artéria descendente anterior foi o vaso mais acometido (57%), seguida pela coronária direita (14,45%). Complicações graves mais frequentes foram choque cardiogênico (3,28%) e parada cardiorrespiratória (0,7%). CONCLUSÃO: Nesta grande coorte brasileira, a SCAD acometeu preferencialmente pacientes jovens e mulheres. A frequência de fatores de risco clássicos para doença arterial coronariana foi pouco comum, sendo o gatilho predominante o estressor emocional. Esta entidade deve ser considerada como diagnóstico diferencial na síndrome coronariana aguda, principalmente em mulheres jovens (< 50 anos).


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Síndrome Coronariana Aguda , Dissecação , Angústia Psicológica
8.
Circulation ; 142(15): 1497-1499, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33044863
9.
Circulation ; 142(15): 1497-1499, Oct. 2020. graf
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1148174
10.
Catheter Cardiovasc Interv ; 96(5): 1046-1055, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31990453

RESUMO

OBJECTIVES: To report clinical, angiographic characteristics, outcomes, and predictors of unsuccessful procedures in patients who underwent chronic total occlusion (CTO) percutaneous coronary interventions (PCI) in Latin America. BACKGROUND: CTO PCI has been increasingly performed worldwide, but there is a lack of information in this region. METHODS: An international multicenter registry was developed to collect data on CTO PCI performed in centers in Latin America. Patient, angiographic, procedural and outcome data were evaluated. Predictors of unsuccessful procedures were assessed by multivariable analysis. RESULTS: We have included data related to 1,040 CTO PCIs performed in seven countries in Latin America (Argentina, Brazil, Chile, Colombia, Ecuador, Mexico, and Puerto Rico). The mean age was 64 ± 10 years, and CTO PCI was performed mainly for angina control (81%) or treatment of a large ischemic area (30%). Overall technical success rate was 82.5%, and it was achieved with antegrade wire escalation in 81%, antegrade dissection/re-entry in 8% and with retrograde techniques in 11% of the successful procedures. Multivariable analysis identified moderate/severe calcification, a blunt proximal cap and a previous attempt as independent predictors of unsuccessful procedures. In-hospital major adverse cardiovascular events (MACE) occurred in 3.1% of the cases, death in 1% and cardiac tamponade in 0.9% CONCLUSIONS: CTO PCI in Latin America has been performed mainly for ischemia relief. Procedures were associated with a success rate above 80% and low incidence of MACE. Predictors of unsuccessful procedures were similar to those previously reported in the literature.


Assuntos
Oclusão Coronária/terapia , Intervenção Coronária Percutânea , Idoso , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , América Latina , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Sistema de Registros , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
11.
Circ. cardiovasc. interv ; 12(11): 1-8, nov., 2019. ilus., graf., tab.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1049984

RESUMO

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field. (AU)


Assuntos
Sistema de Registros , Incidência , Endocardite , Substituição da Valva Aórtica Transcateter
12.
JACC Cardiovasc Interv ; 12(10): 911-920, 2019 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-31122347

RESUMO

OBJECTIVES: This study aimed to compare differences in patient characteristics and clinical outcomes of nonagenarians undergoing transcatheter aortic valve replacement (TAVR) versus patients younger than 90 years of age and to test the predictive accuracy of the logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation), the EuroSCORE II, and the STS-PROM (Society of Thoracic Surgeons Predicted Risk of Mortality) for mortality after TAVR in nonagenarians. BACKGROUND: The prevalence of severe aortic valve stenosis is increasing due to the rising life expectancy. However, there are limited data evaluating outcomes in patients older than 90 years of age. Moreover, the predictive accuracy of risk scores for mortality has not been evaluated in nonagenarian patients undergoing transfemoral TAVR. METHODS: The CENTER (Cerebrovascular EveNts in Patients Undergoing TranscathetER Aortic Valve Implantation) collaboration (N = 12,381) is an international collaboration consisting of 3 national registries, 6 local or multicenter registries, and 1 prospective clinical study, selected through a systematic online search. The primary endpoint of this study was the difference in 30-day all-cause mortality and stroke after TAVR in nonagenarians versus patients younger than 90 years of age. Secondary endpoints included differences in baseline characteristics, in-hospital outcomes, and the differences in predictive accuracy of the logistic EuroSCORE, the EuroSCORE II, and STS-PROM. RESULTS: A total of 882 nonagenarians and 11,499 patients younger than 90 years of age undergoing transfemoral TAVR between 2007 and 2018 were included. Nonagenarians had considerably fewer comorbidities than their counterparts. Nevertheless, rates of 30-day mortality (9.9% vs. 5.4%; relative risk [RR]: 1.8; 95% confidence interval [CI]: 1.4 to 2.3; p = 0.001), in-hospital stroke (3.0% vs. 1.9%; RR: 1.5; 95% CI: 1.0 to 2.3; p = 0.04), major or life-threatening bleeding (8.1% vs. 5.5%; RR: 1.6; 95% CI: 1.1 to 2.2; p = 0.004), and new-onset atrial fibrillation (7.9% vs. 5.2%; RR: 1.6; 95% CI: 1.1 to 2.2; p = 0.01) were higher in nonagenarians. The STS-PROM adequately estimated mortality in nonagenarians, with an observed-expected mortality ratio of 1.0. CONCLUSIONS: In this large, global, patient-level analysis, mortality after transfemoral TAVR was 2-fold higher in nonagenarians compared with patients younger than 90 years of age, despite the lower prevalence of baseline comorbidities. Moreover, nonagenarians had a higher risk of in-hospital stroke, major or life-threatening bleeding, and new-onset atrial fibrillation. The STS-PROM was the only surgical risk score that accurately predicted the risk of mortality in nonagenarians.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Periférico , Artéria Femoral , Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Punções , Ensaios Clínicos Controlados Aleatórios como Assunto , Recuperação de Função Fisiológica , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Índices de Gravidade do Trauma , Resultado do Tratamento
13.
Arq Bras Cardiol ; 111(2): 193-202, 2018 Aug.
Artigo em Inglês, Português | MEDLINE | ID: mdl-30183986

RESUMO

BACKGROUND: Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is mandatory to properly assess PVL, thus improving implantation results and outcomes. OBJECTIVE: To investigate a quantitative angiographic assessment of aortic regurgitation (AR) by videodensitometry before and after BPD. METHODS: Videodensitometric-AR assessments (VD-AR) before and after BPD were analysed in 61 cases. RESULTS: VD-AR decreased significantly from 24.0[18.0-30.5]% to 12.0[5.5-19.0]% (p < 0.001, a two-tailed p < 0.05 defined the statistical significance). The relative delta of VD-AR after BPD ranged from -100% (improvement) to +40% (deterioration) and its median value was -46.2%. The frequency of improvement, no change, and deterioration were 70% (n = 43), 25% (n = 15) and 5% (n = 3), respectively. Significant AR (VD-AR > 17%) was observed in 47 patients (77%) before and in 19 patients (31%) after BPD. CONCLUSIONS: VD-AR after THV implantation provides a quantitative assessment of post-TAVI regurgitation and can help in the decision-making process on performing BPD and in determining its efficacy.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Aortografia , Densitometria , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Gravação em Vídeo
14.
Catheter. cardiovasc. interv ; 92(5): 945-953, Nov. 2018. tab, ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1223467

RESUMO

OBJECTIVES: To explore the rate, the determinants of success, and the hemodynamic impact of balloon postdilatation (BPD) of self-expanding transcatheter heart valves (SE-THVs) Background: BPD is commonly used to optimize valve expansion and reduce paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) without clearly knowing its hemodynamic benefits. METHODS: Patients (n 5 307) who received a SE-THV were stratified according to whether a BPD was performed or not. Patients who received BPD were stratified according to the severity of PVL remaining after BPD into two groups: Successful BPD ( mild PVL 1 BPD) and Failed BPD (moderate-severe PVL 1 BPD). RESULTS: BPD was performed in 121 patients (39.4%) and was successful in 106 patients (87.6% of attempts). A ratio of the postdilatation balloon diameter to the annulus diameter 0.95 was an independent predictor of BPD failure (OR: 10.72 [2.02-56.76], P 5 .005). Peak transvalvular pressure gradient (PG) was lower in the Successful BPD group (14[12-22] mm Hg) than in the Failed BPD group (18[16-23] mm Hg, P 5 .029), and did not rise in either group during follow-up (median [IQR], 364[161-739] days). CONCLUSION: BPD was performed in 39% of patients who received a SE-THV, and was successful in the majority of attempts. BPD failure was more likely in patients with a small postdilatation balloon-to-annulus diameter ratio. Effective BPD improved THV hemodynamic performance, and this was maintained in the intermediate-term post-TAVI.


Assuntos
Substituição da Valva Aórtica Transcateter , Hemodinâmica , Valva Aórtica
15.
Arq. bras. cardiol ; 111(2): 193-202, Aug. 2018. tab, graf
Artigo em Inglês, Português | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-950218

RESUMO

Abstract Background: Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is mandatory to properly assess PVL, thus improving implantation results and outcomes. Objective: To investigate a quantitative angiographic assessment of aortic regurgitation (AR) by videodensitometry before and after BPD. Methods: Videodensitometric-AR assessments (VD-AR) before and after BPD were analysed in 61 cases. Results: VD-AR decreased significantly from 24.0[18.0-30.5]% to 12.0[5.5-19.0]% (p < 0.001, a two-tailed p < 0.05 defined the statistical significance). The relative delta of VD-AR after BPD ranged from -100% (improvement) to +40% (deterioration) and its median value was -46.2%. The frequency of improvement, no change, and deterioration were 70% (n = 43), 25% (n = 15) and 5% (n = 3), respectively. Significant AR (VD-AR > 17%) was observed in 47 patients (77%) before and in 19 patients (31%) after BPD. Conclusions: VD-AR after THV implantation provides a quantitative assessment of post-TAVI regurgitation and can help in the decision-making process on performing BPD and in determining its efficacy.


Resumo Fundamento: A pós-dilatação com balão (PDB) é normalmente necessária para otimização do implante da válvula cardíaca transcateter (THV), uma vez que o "escape" ou leak paravalvar (PVL) após implante de valva aórtica transcateter está associada com desfecho ruim e mortalidade. A avaliação quantitativa da gravidade do PVL antes e após a PDB é mandatória para se avaliar adequadamente o PVL e, assim, melhorar os resultados e os desfechos do implante. Objetivo: Investigar uma avalição angiográfica quantitativa da regurgitação aórtica (RA) por videodensitometria (VD-RA) antes e após a PDB. Métodos: Resultados da VD-RA antes e após a PDB foram analisados em 61 casos. Resultados Houve diminuição significativa da VD-RA de 24,0(18,0-30,5)% para 12,0(5,5-19,0)% (p < 0,001; p < 0,05 bilateral foi definido como significância estatística). O delta relativo de VD-RA após a PDB variou de -100% (melhora) a +40% (piora) e o valor mediano foi -46,2%. As frequências de melhora, ausência de mudança, e piora foram 70% (n = 43), 25% (n = 15) e 5% (n = 3), respectivamente. Observou-se RA significativo (VD-RA > 17%) em 47 pacientes (77%) antes e em 19 pacientes (31%) após a PDB. Conclusões: A VD-RA após o implante de THV possibilita a avaliação quantitativa da regurgitação pós-TAVI, e pode auxiliar na tomada de decisão quanto à realização ou não da PDB, bem como na avaliação de sua eficácia.


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Complicações Pós-Operatórias/diagnóstico por imagem , Gravação em Vídeo , Índice de Gravidade de Doença , Aortografia , Densitometria , Substituição da Valva Aórtica Transcateter/efeitos adversos
16.
Catheter Cardiovasc Interv ; 92(5): 945-953, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29520970

RESUMO

OBJECTIVES: To explore the rate, the determinants of success, and the hemodynamic impact of balloon postdilatation (BPD) of self-expanding transcatheter heart valves (SE-THVs) BACKGROUND: BPD is commonly used to optimize valve expansion and reduce paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) without clearly knowing its hemodynamic benefits. METHODS: Patients (n = 307) who received a SE-THV were stratified according to whether a BPD was performed or not. Patients who received BPD were stratified according to the severity of PVL remaining after BPD into two groups: Successful BPD (≤mild PVL + BPD) and Failed BPD (moderate-severe PVL + BPD). RESULTS: BPD was performed in 121 patients (39.4%) and was successful in 106 patients (87.6% of attempts). A ratio of the postdilatation balloon diameter to the annulus diameter ≤0.95 was an independent predictor of BPD failure (OR: 10.72 [2.02-56.76], P = .005). Peak transvalvular pressure gradient (PG) was lower in the Successful BPD group (14[12-22] mm Hg) than in the Failed BPD group (18[16-23] mm Hg, P = .029), and did not rise in either group during follow-up (median [IQR], 364[161-739] days). CONCLUSION: BPD was performed in 39% of patients who received a SE-THV, and was successful in the majority of attempts. BPD failure was more likely in patients with a small postdilatation balloon-to-annulus diameter ratio. Effective BPD improved THV hemodynamic performance, and this was maintained in the intermediate-term post-TAVI.


Assuntos
Insuficiência da Valva Aórtica/prevenção & controle , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Hemodinâmica , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Brasil , Feminino , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
EuroIntervention ; 13(10): 1157-1165, 2017 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-28691910

RESUMO

AIMS: In addition to patients with pure/predominant aortic stenosis (PAS), real-world transcatheter aortic valve implantation (TAVI) referrals include patients with mixed aortic valve disease (MAVD; severe stenosis+moderate-severe regurgitation). We sought to compare TAVI outcomes in patients with MAVD vs. PAS. METHODS AND RESULTS: Out of 793 consecutive patients undergoing TAVI, 106 (13.4%) had MAVD. Patients with MAVD were younger and had a higher operative risk, a more severe adverse cardiac remodelling, and a worse functional status than patients with PAS. Moderate-severe prosthetic valve regurgitation (PVR) was significantly more frequent in patients with MAVD than in patients with PAS (15.7% vs. 3.6%, p=0.003), even after propensity-score and multivariable adjustments. Moderate-severe PVR was associated with increased one-year mortality in patients with PAS (log-rank p=0.002), but not in patients with MAVD (log-rank p=0.27). Eventually, all-cause and cardiac mortality as well as the functional capacity were similar in the two study groups up to one year. CONCLUSIONS: A significant proportion of patients referred for TAVI in a real-world registry has MAVD. Moderate-severe AR at baseline can influence the rate and modify the clinical sequelae of post-TAVI PVR. Eventually, clinical outcomes in patients with MAVD are comparable to those in patients with PAS in the acute and midterm phases, in spite of a baseline higher risk. MAVD should not be considered a contraindication for TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cardiopatias Congênitas/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Cateterismo Cardíaco/métodos , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
Clin Res Cardiol ; 106(9): 752-759, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28444455

RESUMO

BACKGROUND: Patients with degenerative aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI) typically have advanced cardiac and vascular adverse remodeling and multiple comorbidities and, therefore, might not recover a normal functional capacity after valve replacement. We sought to investigate the prevalence, the predictors, and the prognostic impact of residual impairment of functional capacity after TAVI. METHODS AND RESULTS: Out of 790 patients undergoing TAVI with impaired functional capacity (NYHA II-IV) at baseline, NYHA functional class improved in 592 (86.5%) and remained unchanged/worsened in 92 (13.5%) at follow-up [median (IQR): 419 (208-807) days] after TAVI. Normal functional capacity (NYHA I) was recovered in 65.5% (n = 448) of patients, while the rest had variable degrees of residual impairment. On multivariable regression analysis, atrial fibrillation [odds ratio-OR, 2.08 (1.21-3.58), p = 0.008], low-flow-low-gradient AS [OR, 1.97 (1.09-3.57), p = 0.026], chronic obstructive pulmonary disease [OR, 1.92 (1.19-3.12), p = 0.008], and lower hemoglobin at baseline [OR, 1.11 (1.01-1.21) for each g% decrement, p = 0.036] were independently associated with residual impairment of functional capacity. All-cause and cardiac mortality were significantly higher in those with residual impairment of functional capacity than in those in NYHA I class [hazard ratio-HR: 2.37 (95% CI: 1.51-3.72), p < 0.001 and 2.16 (95% CI: 1.08-4.35), p = 0.030, respectively]. Even mild residual functional impairment (NYHA II) was associated with a higher all-cause [HR: 2.02 (95% CI: 1.10-3.72), p = 0.023] and cardiac [HR: 2.08 (95% CI: 1.42-3.07), p < 0.001] mortality. CONCLUSION: Residual impairment of functional capacity is common after TAVI and is independently associated with increased mortality. Predictors of residual impairment of functional status are predominantly patient-rather than procedure-related.


Assuntos
Estenose da Valva Aórtica/cirurgia , Insuficiência Cardíaca/fisiopatologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Prevalência , Prognóstico , Modelos de Riscos Proporcionais , Doença Pulmonar Obstrutiva Crônica/complicações , Sistema de Registros , Análise de Regressão , Fatores de Risco , Resultado do Tratamento